Pressure instrument
Contact Information
Address: Building 10, Zhonglian Industrial Park, Zhongbei Town, Xiqing District, Tianjin
Telephone:+86-22-59958977
Mailbox:350332639@qq.com
Proline Promass S 500 Coriolis Mass Flow Meter
Classification:
Key words:
- Product Description
-
- Commodity name: Proline Promass S 500 Coriolis Mass Flow Meter
- Commodity ID: Proline Promass S 500
Easy-to-clean, self-draining single-tube system, paired with a split-type transmitter offering up to 4 input/output channels.
Application areas
The Promass S 500 single-tube mass flowmeter is easy to clean and features self-draining capabilities, making it fully compliant with the stringent hygiene requirements of the food and beverage industry. Its innovative split transmitter design ensures installation flexibility and operational safety even under demanding process conditions. The device offers multiple communication options, including up to four configurable inputs/outputs, fieldbus, industrial Ethernet, and wireless HART, enabling seamless system integration. Additionally, it comes equipped with built-in Heartbeat Technology, continuously guaranteeing compliance at all times.
- The measurement principle is unaffected by the physical properties of the fluid (e.g., viscosity and density).
- In hygienic applications, a dedicated flow meter is required for optimal self-draining applications.
Instrument Features
- Multiple hygienic process connections
- 3A Certification and EHEDG Certification
- CIP/SIP cleaning enables rapid recovery
- Split-type instrument with up to 4 input/output channels, hygienic process connection, and sensor housing protection rating: IP69
- Backlit display, touch-key control, and WLAN access
- Sensors and transmitters are connected via standard cables.
Advantages
- High process safety: Self-priming measuring tube design for easy cleaning
- Fewer process measurement points: Multi-parameter measurements (flow, density, temperature)
- Save installation space: No front or rear straight pipe section required
- View complete process and diagnostic information: Offers multiple user-defined input/output combination methods and Ethernet connectivity.
- Reducing Complexity and Diversity: User-Defined Input/Output Features
- Built-in verification feature: Equipped with Heartbeat Technology
Product Specifications
- Maximum measurement error
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Density (liquid): ±0.0005 g/cm³- Measurement range
0 to 70,000 kg/h (0 to 2,570 lb/min)
- Medium temperature range
–50 to +150 °C (–58 to +302 °F)
- Maximum process pressure
PN 40, Class 150, 20K
- Liquid-contact component material
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)