Pressure instrument

Contact Information

Address: Building 10, Zhonglian Industrial Park, Zhongbei Town, Xiqing District, Tianjin

Telephone:+86-22-59958977

Mailbox:350332639@qq.com

+
  • SMARTLINE STT850 温度变送器.webp

SMARTLINE® STT850 Temperature Transmitter

STT850 is a high-performance temperature transmitter that delivers exceptional measurement accuracy and stability across a wide range of process and ambient temperatures. The SmartLine® has undergone rigorous testing and meets Experion® PKS standards, ensuring superior compatibility and seamless integration capabilities. As a result, SmartLine® products effortlessly meet the demanding requirements of temperature measurement applications.

Classification:

Key words:


24-hour service hotline:+86-22-59958977

 

Bidding authorization:+86 13821081088


  • Product Description
    • Commodity name: SMARTLINE® STT850 Temperature Transmitter
    • Commodity ID: SMARTLINE STT850

    STT850 is a high-performance temperature transmitter that delivers exceptional measurement accuracy and stability across a wide range of process and ambient temperatures. The SmartLine® has undergone rigorous testing and meets Experion® PKS standards, ensuring superior compatibility and seamless integration capabilities. As a result, SmartLine® products effortlessly meet the demanding requirements of temperature measurement applications.

    High-performance performance

    • RTD's digital accuracy can reach 0.10℃
    • Stability: 0.01% per year for the URL, maintained over 10 years
    • The update time for the single-input model is 125ms.
    • The update time for the dual-input model is 250ms.

    Reliable measurement

    • Built-in electrical isolation feature
    • It can achieve differential/average/redundant/segmented measurements.
    • Dual-compartment structure
    • Features sensor open-circuit detection functionality
    • Comprehensive self-diagnosis function
    • Fully meets SIL 2/3 requirements
    • Up to 15 years of warranty is available.
    • Supports Namur 107 Extended Diagnostic Function
    • Supports Namur 89 Open-Circuit Detection Function
    • Directly input the Callendar-Van Dusen parameters R0, α, δ, and β for calibrating the RTD sensor (not applicable to DE protocol).

    Low total cost of ownership

    • Various temperature sensor inputs
    • Offering dual-sensor input options
    • Multiple local display features
    • Modular structure
    • External zero, span, and configuration functions
    • Power polarity can be connected arbitrarily.
    • Switch output options (HART protocol only)

    Communication/Output Options

    • 4-20mA DC
    • Honeywell Digital Enhancement (DE) Protocol
    • HART ® (Version 7.0)
    • FOUNDATION™ Fieldbus compliant with ITK 6.1.2 standard

Product Consulting