Rosemount Flexim PIOX S831 Non-Invasive Ultrasonic Liquid Analyzer

The Flexim PIOX S831 Liquid Analyzer is certified for operation in hazardous areas (ATEX/ICEx Zone 1, FM Class I Groups 1+2). It determines liquid concentration and density using an external clamp-on ultrasonic sensor installed on the outer side of the pipeline. Non-invasive technology is the preferred system when safety and reliability requirements for substances and processes are particularly stringent. The PIOX S utilizes dynamic inference based on sound velocity and temperature measurements to accurately calculate fluid density. For binary liquids such as acids or carbonated beverages, sound velocity maintains a fixed relationship with both concentration and density. Additionally, this flowmeter employs the time-of-flight differential method to measure volumetric flow rate, enabling it to determine mass flow rates for liquids of varying densities.

Classification:

Key words:


24-hour service hotline:+86-22-59958977

 

Bidding authorization:+86 13821081088


  • Product Description
    • Commodity name: Rosemount Flexim PIOX S831 Non-Invasive Ultrasonic Liquid Analyzer
    • Commodity ID: Flexim-Piox-S831

    The Flexim PIOX S831 Liquid Analyzer is certified for operation in hazardous areas (ATEX/ICEx Zone 1, FM Class I Groups 1+2). It determines liquid concentration and density using an external clamp-on ultrasonic sensor installed on the outer side of the pipeline. Non-invasive technology is the preferred system when safety and reliability requirements for substances and processes are particularly stringent. The PIOX S utilizes dynamic inference based on sound velocity and temperature measurements to accurately calculate fluid density. For binary liquids such as acids or carbonated beverages, sound velocity maintains a fixed relationship with both concentration and density. Additionally, this flowmeter employs the time-of-flight differential method to measure volumetric flow rate, enabling it to determine mass flow rates for liquids of varying densities.

    Specifications

    • Fluid Type

    All liquids

    • Measurement Parameters

    Speed of Sound
    Concentration (g/L), mass percentage, and volume percentage
    Density
    Other measurable parameters

    • Accuracy

    This instrument requires on-site calibration.*

    • Repetitiveness

    0.1% w%

    • Process Temperature

    -40…200 °C (-40…392 °F) / WI: -200…630 °C (-328 °F…+1112 °F)**

    • Certificate/Certification

    ATEX/IECEx Zone 1/Zone 2, FM Class I Division 2

    • Power Supply

    100–230 VAC, 24 VDC, 12 VDC

    • Pipe Size

    6…6500 mm (0.24…255.9 in)

    • Output

    4-20mA Active/Passive
    4-20mA HART Active/Passive
    Pulse/Frequency/Binary

    • Input

    Pt100/Pt1000
    4-20mA Active/Passive
    Digital Input

    • Communication Protocol

    Modbus RTU/TCP
    BACnet MSTP/IP
    Profibus PA
    FOUNDATION Fieldbus


    Features

    • Suitable for all pipe materials—such as glass, steel, plastic, and more.
    • Suitable for almost all acids, corrosives, and a variety of other toxic liquids.
    • Suitable for ATEX, IECEX, and FM areas
    • No downtime required during installation.
    • Maintenance-free

Product Consulting