Rosemount 8732E Field-Mounted Electromagnetic Flow Transmitter
Classification:
Key words:
- Product Description
-
- Commodity name: Rosemount 8732E Field-Mounted Electromagnetic Flow Transmitter
- Commodity ID: Rosemount 8732E Field-Mount Magnetics
The dual-chamber transmitter housing isolates the internal components from the external environment. Advanced diagnostics and a local operator interface with a protective glass window provide excellent insight into the process.
Specifications
- Sensor Compatibility
Compatible with Rosemount 8705, 8711, and 8721 sensors. Also compatible with AC- and DC-powered sensors from other manufacturers.
- Transmitter Coil Drive Current
500mA
- Flow Rate Range
Capable of handling forward and reverse flow signals for all sensor sizes, with flow velocities ranging from 0.04 to 39 ft/s (0.01 to 12 m/s). The full-scale range is continuously adjustable between -39 and 39 ft/s (-12 to 12 m/s).
- Electrical Conductivity Limit
The process liquid must have a conductivity of 5 microsiemens per centimeter (5 mS/cm) or greater.
- Power Supply
90–250 VAC, 50/60 Hz, or 12–42 VDC
- Power supply fuse
90-250VAC System
1A, 250V, I2t rating, fast-acting Bussman AGC-1, Littlefuse 31201.5HXP
12-42 VDC System
3 Amp, 250V, I2t-rated, 14 A²s Fast-Blow Fuse Link 3AG 3-R, Littelfuse 312003P, Schurter 0034.5135- Power supply fuse
15 W Maximum - DC
40 VA Maximum - AC- Connect the power supply
Communication: Maximum 35.7 A (< 5 ms), at 250 VAC
DC: Maximum 42A (< 5ms), at 42VDC
Features
- Intelligent instrument self-verification continuously monitors the operational status and performance of instruments without interrupting the production process.
- Dual-chamber transmitter housing designed to prevent moisture ingress. Advanced digital signal processing enhances process management.
- High-process-noise diagnostics with optional coil-drive frequency options optimize control over noise-sensitive applications. When the pipeline is empty, adjustable empty-pipeline diagnostics can minimize issues and erroneous readings.
- Diagnosis for Grounding and Wiring Error Detection, enabling rapid verification of installation integrity.
- Configure the optical switch without removing the cover, simplifying adjustment operations in hazardous environments.
- The versatility of the transmitter helps reduce inventory, and the interface remains consistent across all electromagnetic flowmeter sensors.
Product Consulting
Related Products