Pressure instrument

Contact Information

Address: Building 10, Zhonglian Industrial Park, Zhongbei Town, Xiqing District, Tianjin

Telephone:+86-22-59958977

Mailbox:350332639@qq.com

+
  • prod-flow-micro-motion-2400-pdp-1-straightview.gif
  • prod-flow-micro-motion-2400-pdp-3-sideview.jpg
  • prod-flow-micro-motion-2400-pdp-2-topview.gif
  • 2400s.png

Micro Motion 2400S Compact Integrated Mounting Transmitter

Integrated architecture design makes process information more accessible, and the compact 2400S all-in-one transmitter delivers outstanding performance even in the most challenging applications—such as gas trapping, batch processing, and loading scenarios.

Classification:

Key words:


24-hour service hotline:+86-22-59958977

 

Bidding authorization:+86 13821081088


  • Product Description
    • Commodity name: Micro Motion 2400S Compact Integrated Mounting Transmitter
    • Commodity ID: 2400S

    Integrated architecture design makes process information more accessible, and the compact 2400S all-in-one transmitter delivers outstanding performance even in the most challenging applications—such as gas trapping, batch processing, and loading scenarios.

    Specifications

    • Output variable

    Quality and Volumetric Flow

    Product Net Content/Flow Rate

    Temperature

    Density

    Concentration

    • Local display

    Standard user interface with a 2-line LCD panel

    Two coupling latches for HART/Bell 202 connection (transmitter housing cover must be removed)

    Two local-operated membrane buttons (transmitter housing cover must be removed)

    Glass or plastic lens options

    • Power Supply

    Auto-switching AC/DC input, with automatic power voltage recognition

    85–265 VAC, 50/60 Hz, Normal: 4 W, Maximum: 7 W

    18–100 VDC, normal 4 watts, maximum 7 watts

    Complies with Low Voltage Directive 2006/95/EC 61010-1 (IEC 61010-1), meeting Installation (Overvoltage) Category II and Pollution Degree 2.

    • Input/Output Signals (Analog Output Options)

    Channel A:

    A 4-20 mA active output

    The non-intrinsically safe channel B (configurable) is one of the following:

    An active or passive frequency output

    An active or passive discrete output

    A passive or active discrete input

    • Input/Output Signals (PROFIBUS-DP Option)

    Digital 2-way PROFIBUS-DP signal

    • Input/Output Signals (DeviceNet Option)

    Digital 2-Way DeviceNet Signal (Discontinued)

    HARTBell 202 signal is superimposed on the primary milliamp output.

    • HART

    Communication is not available for PROFIBUS-DP and DeviceNet transmitter versions.

    • Installation Options

    On-site installation, integrated with sensors

    • Application Type

    Continuous Process Control

    Two-phase flow/entrained gas

    Instrument Verification

    • Danger Certification

    C1D2

    Zone 2


    Features

    • By adopting MVD digital processing technology, performance diagnostics can be performed in gas-inclusion applications as well as in empty-to-full and full-to-empty batch applications.
    • Smart meter self-verification ensures real-time process measurement integrity.
    • It boasts excellent two-phase flow measurement capabilities for batch, charging, and gas-entrainment applications.
    • The display screen features optical buttons, allowing you to view information without removing the transmitter cover.
    • Obtained Class 1, Div. 2 [Zone 2] approval for hazardous locations (sensors and transmitters)