Pressure instrument
Contact Information
Address: Building 10, Zhonglian Industrial Park, Zhongbei Town, Xiqing District, Tianjin
Telephone:+86-22-59958977
Mailbox:350332639@qq.com
Micro Motion 5700 Field-Installable Transmitter
Classification:
Key words:
- Product Description
-
- Commodity name: Micro Motion 5700 Field-Installable Transmitter
- Commodity ID: Micro Motion 5700
The Model 5700 transmitter delivers outstanding measurement technology and service support, featuring an intuitive design that simplifies solutions to ensure measurement confidence, valuable process insights, and enhanced productivity. Its data history function captures rich information about process events, fluid quality, and measurement stability—providing both long-term and short-term data. Additionally, the zero-point calibration tool helps users verify instrument zero settings, analyze process conditions, and promptly identify potential zeroing issues.
Specifications
Local display
- Graphical Backlit Display
- Four-key optical control system
- Flow meter status LED indicator
- Supports English, German, French, Spanish, Portuguese, Russian, Chinese, and Japanese, among other languages.
Electricity
- AC/DC input automatically switches, seamlessly recognizing the power voltage.
- 85 to 2405 VAC, 50/60 Hz, typical value 6 W, maximum 11 W
- 18 to 100 VDC, typical value 6 W, maximum 11 W
- Compliant with the European Low-Voltage Directive 2006/95/EC, according to IEC 61010-1, Version 3.0, June 2010; Overvoltage Category II, Pollution Degree 2
Universal Service Port
- The universal server port enables connection and data transmission using standard, off-the-shelf equipment.
Configurable I/O Type
Up to 5 authorized channels are available for the following configurations:
- 1 to 3 4-20 mA outputs
- 1 to 3 pulse outputs
- 1 to 3 discrete outputs
- 1 to 2 discrete inputs
- 1 mA Input
- 1 Modbus/RS-485
Channel A: Milliamps/HART
Channel B: Milliamps/FO/DO
Channel C: Milliamps/FO/DO/DI
Channel D: Milliamp Input/FO/DO/DI
Channel E: Modbus RS-485Communication Protocol
Wireless HART
- Wireless HART can use the 775 Smart Wireless THUM Adapter.
FOUNDATION Fieldbus Version
- FOUNDATION Fieldbus Channel
- Milliampere output
- Pulse Output
PROFIBUS-PA Version
- PROFIBUS-PA Channel
- Milliampere IS Output
- Pulse IS Output
Wi-Fi Display Option: The Wi-Fi Display Option supports peer-to-peer wireless communication, making it easy to configure and characterize instruments, download historical record files, and run the smart instrument’s self-check function for troubleshooting. Available only for the 5700 Configuration I/O Model.
Inherently Safe Type
Up to 4 authorized IS channels are available for the following configurations:
- Channel A: Milliamps/HART
- Channel B: Milliamps
- Channel C: Milliamps/FO
- Channel D: FO
- Channel E: Unused
SIL-certified devices—using an internal feedback loop to verify milliamp output
Ethernet-based
- Dual Ethernet ports, enabling simultaneous support for EtherNet/IP, Modbus TCP, and PROFINET on a single device.
- Includes additional channels configurable as milliamp output, pulse output, discrete output, or discrete input
- Pre-installed M12 quick connectors are available as an optional feature.
Installation Options
- On-site installation options with aluminum and stainless steel housings
- Integrated installation for Micro Motion ELITE (CMFS), F Series, H Series, R Series, or T Series Coriolis sensors (aluminum models only)
- Split-type installation compatible with any 4-wire or 9-wire Micro Motion ELITE®, F Series, H Series, R Series, or T Series Coriolis sensors (aluminum and stainless steel models)
Application Type
- Smart Meter Self-Verification Professional Application
- Discrete Batch Control
- Petroleum Measurement and API Calibration Options
- Concentration Measurement
- Advanced Phase Measurement for Two-Phase Flow Remediation
- Application of Gas Segmented Linearization
Certificate/Certification
Hazard Certification
- Class I, Zone 1
- Class I, Zone 2
- Zone 1
- Zone 2
SIL/SIS Certification
- 5700 Configuration I/O and intrinsically safe components have been certified for single-use SIL2 and multiple-use SIL3 safety applications, compliant with IEC 61508.
Features
- Utilize the local Ethernet architecture and connectors for quick, flexible installation.
- Achieve faster response speeds and deliver superior performance even in more challenging applications such as instrument calibration, filling, dispensing, and batching.
- Leverage data history to gain short-term and long-term insights into process events, fluid quality, and measurement stability. Monitor additional process measurements using up to 5 fully configurable I/O channels.
- Using smart meters for self-verification allows you to check the instrument's operational status within 90 seconds.
- Using zero-point verification allows for easy confirmation of calibration results whenever the instrument needs to be recalibrated to zero.
- It can display multiphase flow events in real time, enhancing process control while minimizing the time and specialized expertise required for installing and operating flow meters.
Product Consulting
Related Products