Pressure instrument

Contact Information

Address: Building 10, Zhonglian Industrial Park, Zhongbei Town, Xiqing District, Tianjin

Telephone:+86-22-59958977

Mailbox:350332639@qq.com

+
  • Proline Promass E 500.png

Proline Promass E 500 Coriolis Mass Flow Meter

Coriolis mass flow meter, paired with a split-type transmitter featuring up to 4-channel input/output capabilities.

Classification:

Key words:


24-hour service hotline:+86-22-59958977

 

Bidding authorization:+86 13821081088


  • Product Description
    • Commodity name: Proline Promass E 500 Coriolis Mass Flow Meter
    • Commodity ID: Proline Promass E 500

    Coriolis mass flow meter, paired with a split-type transmitter featuring up to 4-channel input/output capabilities.

    Application areas

    The Promass E is robust and durable, offering a cost-effective, long-term solution for high-precision liquid and gas measurements in a wide range of standard applications across various industries. Paired with the innovative split transmitter, the Promass E 500 delivers maximum installation flexibility and superior operational safety—even under demanding process conditions. Additionally, Heartbeat Technology ensures measurement reliability while extending the interval between recalibrations.

    • The measurement principle is unaffected by the physical properties of the fluid (e.g., viscosity and density).
    • High-precision measurement of liquids and gases is widely used in standard applications.

    Instrument Features

    • Integrated dual-measurement tube sensor
    • Media temperature: max. +150 °C (+302 °F)
    • Process pressure: max. 100 bar (1450 psi)
    • Split-type instrument, with up to 4 input/output channels
    • Backlit display, touch-key control, and WLAN access
    • Sensors and transmitters are connected via standard cables.

    Advantages

    • Economic Use: Multipurpose Instrument—The Preferred Alternative to Traditional Volumetric Flow Meters
    • Fewer process measurement points: Multi-parameter measurements (flow, density, temperature)
    • Save installation space: No front or rear straight pipe section required
    • View complete process and diagnostic information: Offers multiple user-customizable input/output combination methods and Ethernet connectivity.
    • Reducing Complexity and Diversity: User-Defined Input/Output Capabilities
    • Built-in verification feature: Equipped with Heartbeat Technology

    Product Specifications

    • Maximum measurement error

    Mass flow (liquid): ±0.15% (standard), ±0.10% (optional)
    Volume flow (liquid): ±0.15 %
    Mass flow (gas): ±0.50 %
    Density (liquid): ±0.0005 g/cm³

    • Measurement range

    0 to 180,000 kg/h (0 to 6,615 lb/min)

    • Medium temperature range

    –40 to +150 °C (–40 to +302 °F)

    • Maximum process pressure

    PN 100, Class 600, 63K

    • Liquid-contact component material

    Measuring tube: 1.4539 (904L)
    Connection: 1.4404 (316/316L)