Pressure instrument

Contact Information

Address: Building 10, Zhonglian Industrial Park, Zhongbei Town, Xiqing District, Tianjin

Telephone:+86-22-59958977

Mailbox:350332639@qq.com

+
  • Proline Promass E 200.png

Proline Promass E 200 Coriolis Mass Flow Meter

Standard Coriolis mass flow meter. True two-wire loop power supply technology

Classification:

Key words:


24-hour service hotline:+86-22-59958977

 

Bidding authorization:+86 13821081088


  • Product Description
    • Commodity name: Proline Promass E 200 Coriolis Mass Flow Meter
    • Commodity ID: Proline Promass E 200

    Standard Coriolis mass flow meter. True two-wire loop power supply technology

    Application areas

    Promass is robust and durable, delivering consistently stable measurements—making it a reliable solution for high-precision liquid and gas flow measurement in standard applications across the chemical industry. The Proline E 200 is a true loop-powered, two-wire transmitter that offers cost-effective performance while seamlessly integrating into existing systems. Featuring an intrinsically safe design (Ex ia), this flowmeter ensures maximum operational safety even in hazardous areas. Plus, Heartbeat Technology guarantees continuous process reliability, keeping your operations secure at all times.

    • The measurement principle is unaffected by the physical properties of the fluid (such as viscosity or density).
    • High-precision measurement of liquids and gases in standard application scenarios.

    Instrument Features

    • Dual-measurement tube sensor with a compact design
    • Maximum media temperature: +150 °C (+302 °F)
    • Process pressure: Up to 100 bar (1450 psi)
    • Two-wire loop power supply technology
    • Durable, robust dual-chamber outdoor housing
    • Factory Safety: Certified to Multiple International Standards (SIL, Explosion-Proof)

    Advantages

    • High-cost-performance, multi-purpose instrument—your ideal replacement for traditional volumetric flowmeters.
    • Few process measurement points: Multivariate measurements (flow, density, temperature)
    • Minimal installation space required: No front or rear straight pipe section length requirements for installation
    • Easy wiring: The instrument features a dedicated wiring compartment.
    • Operational Safety: Equipped with a backlit display featuring touch-key operation, allowing you to operate without opening the instrument.
    • With self-checking functionality: Utilizing Heartbeat Technology

    Product Specifications

    • Maximum measurement error

    Mass flow (liquid): ±0.25% (standard)
    Volume flow (liquid): ±0.25 %
    Mass flow (gas): ±0.50 %
    Density (liquid): ±0.0005 g/cm³

    • Measurement range

    0 to 70,000 kg/h (0 to 2,570 lb/min)

    • Medium temperature range

    –40 to +150 °C (–40 to +302 °F)

    • Maximum process pressure

    PN 100, Class 600, 63K

    • Liquid-contact component material

    Measuring tube: 1.4539 (904L)
    Connection: 1.4404 (316/316L)