Pressure instrument
Contact Information
Address: Building 10, Zhonglian Industrial Park, Zhongbei Town, Xiqing District, Tianjin
Telephone:+86-22-59958977
Mailbox:350332639@qq.com
Proline Promass F 300 Coriolis Mass Flow Meter
Classification:
Key words:
- Product Description
-
- Commodity name: Proline Promass F 300 Coriolis Mass Flow Meter
- Commodity ID: Proline Promass F 300
High-precision flow meter, robust and durable, paired with a user-friendly, one-piece transmitter.
Application areas
The Promass F is a proven, high-precision sensor that remains unaffected by fluctuations and harsh environmental conditions, making it ideal for a wide range of applications. When paired with an integrated transmitter, the Promass F 300 offers exceptional flexibility and seamless system integration: operation and wiring are conveniently located on the same side of the transmitter. Optional features include remote display capabilities, freely configurable I/O functions, and versatile system bus integration options. Additionally, Heartbeat Technology ensures measurement reliability while extending calibration intervals.
- The measurement principle is unaffected by the physical properties of the fluid (e.g., viscosity and density).
- Delivering the highest measurement performance in demanding, changing process conditions for both liquid and gas applications.
Instrument Features
- Quality flow measurement error: ±0.05% (PremiumCal)
- Media temperature: -196…350 °C (-320…662 °F)
- Nominal diameter: DN 8...250 (3/8...10")
- Integrated dual-chamber outdoor enclosure, supporting up to 3 input/output channels
- Backlit display, touch-key control, and WLAN access
- Providing detachable display units
Advantages
- Maximum process safety: Unaffected by fluctuations and harsh operating conditions.
- Fewer process measurement points: Multi-parameter measurements (flow, density, temperature)
- Save installation space: No straight pipe section length requirements—front or rear
- View complete process and diagnostic information: Offers multiple user-defined input/output combination methods and Ethernet connectivity.
- Reducing Complexity and Diversity: User-Defined Input/Output Capabilities
- Built-in verification feature: Equipped with Heartbeat Technology
Product Specifications
- Maximum measurement error
Mass flow rate (liquid): ±0.10% (standard), 0.05% (optional)
Volumetric flow rate (liquid): ±0.10%
Mass flow rate (gas): ±0.35%
Density (liquid): ±0.0005 g/cm³- Measurement range
0...2,200,000 kg/h (0...80,840 lb/min)
- Medium temperature range
Standard type: –50…+150 °C (–58…+302 °F)
Optional: –50…+240 °C (–58…+464 °F)
High-temperature version: –50…+350 °C (–58…+662 °F)
Optional: –196…+150 °C (–320…+302 °F)- Maximum process pressure
PN 100, Cl. 600, 63K
- Liquid-contact component material
Measurement tubes: 1.4539 (904L), 1.4404 (316/316L), Alloy C22 2.4602 (UNS N06022) alloys
Connection sections: 1.4404 (316/316L), Alloy C22 2.4602 (UNS N06022), and 1.4301 (F304)