Pressure instrument
Contact Information
Address: Building 10, Zhonglian Industrial Park, Zhongbei Town, Xiqing District, Tianjin
Telephone:+86-22-59958977
Mailbox:350332639@qq.com
Dosimag Electromagnetic Flow Meter
Classification:
Key words:
- Product Description
-
- Commodity name: Dosimag Electromagnetic Flow Meter
- Commodity ID: Dosimag
The flow meter features a hygienic design and an integrated, fully welded structure, ensuring exceptionally high repeatability.
Application areas
The Dosimag electromagnetic flowmeter is specifically designed for filling and volumetric feeding applications involving highly conductive liquids in the food & beverage and life sciences industries, where stringent requirements are critical. Compact and easy to install even in tight, confined spaces, the Dosimag is the ideal choice for system integrators, skid-mounted equipment manufacturers, and equipment makers alike. It measures volumetric flow directly and supports bidirectional flow measurement—unaffected by variations in pressure, density, temperature, or viscosity.
The sensor is compact and robust, designed for durability, with three electronic components offering users flexible options:
- Pulse/frequency/status output type, ideal for cost-effective filling applications
- Intelligent pulse-output type supporting IO-Link communication, featuring continuous digital communication for easy debugging and archival recording, delivering real-time process information, optimizing filling process conditions, and enabling predictive maintenance.
- Models with batch processing capabilities perform dynamic volume correction via Modbus RTU communication and support advanced filling control.
Advantages
- Excellent and stable performance — delivering high-precision, highly repeatable measurements within short filling cycles
- Supports IO-Link communication for real-time digital data exchange, making instrument debugging easier while ensuring data is always readily available.
- Compact and compact, optimizing the footprint of the machine setup
- Built-in batch processing feature—flow meters solve the challenges of filling management.
- Automatically restores data, making maintenance operations easier.
- Compliant with global industry standards – EHEDG, 3-A, FCM, cGMP
- Resistant to SIP and CIP processes
Product Specifications
- Maximum measurement error
±0.25% o.r. ± 1–4 m/s (3.3–13 ft/s)
±0.5% of the reading ± 1 mm/s (0.04 in/s)
±5% o.r.- Measurement range
0.14...1.66 L/s (0.035...0.44 gal/s)
- Medium temperature range
EPDM Sealing Ring: –20…+130 °C (–4…+266 °F)
Silicone sealing ring: -20…+130 °C (–4…+266 °F)
Viton seal: 0…+150 °C (+32…+302 °F)- Maximum process pressure
PN 16
- Liquid-contact component material
Lining: PFA
Electrodes: 1.4435 (316L), Alloy C22 2.4602 (UNS N06022), tantalum, platinum
Product Consulting
Related Products