- Product Description
-
- Commodity name: 8800 Series Vortex Flow Meter
- Commodity ID: 8800
The Rosemount 8800 Series vortex flowmeter boasts exceptional stability, featuring a gasket-free, non-clogging meter body that eliminates potential leak points, enhances reliability, and minimizes unexpected process shutdowns. Designed with a unique isolation sensor, Emerson Rosemount’s 8800 vortex flowmeter allows for easy replacement of both flow and temperature sensors—without compromising the process seal.
Specifications
Flow meter accuracy
Use 8800 MultiVariable Flow meter MTA/MCA Option), obtain the water mass flow rate ± 0.70% Precision of Use 8800 MultiVariable Flow meter MTA/MCA Option), obtain the water mass flow rate ± 2% Precision of Use 8800 MultiVariable Flow meter MPA Option), the steam pressure is achieved as 30 psia To 2,000 psia Flow rate ± 1.3% Precision of Use 8800 MultiVariable Flow meter MCA Option), the steam pressure is achieved as 150 psia Flow rate ± 1.2% Precision of Use 8800 MultiVariable Flow meter MCA Option), the steam pressure is achieved as 300 psia Flow rate ± 1.3% Precision of Use 8800 MultiVariable Flow meter MCA Option), the steam pressure is achieved as 800 psia Flow rate ± 1.6% Precision of Use 8800 MultiVariable Flow meter MCA Option), the steam pressure is achieved as 2,000 psia Flow rate ± 2.5% Precision of Liquid volume flow rate ± 0.65% Accuracy (uncompensated) Gas and Steam Volumetric Flow Rate ± 1% Accuracy (uncompensated)
Measurement range ratio
38:1
Output
4-20mA , based on HART® Or 7
4-20mA , based on HART® 5 Or 7 And adjustable pulse output
FOUNDATION Fieldbus ITK6 , with 2 A simulated input module, 1 A spare link activity scheduler functional block, 1 An integrator function block and 1 One PID Functional block
With device status and 4 Of the variable Modbus RS-485
Liquid-contact material
Stainless steel; 316 / 316L And CF3M
Nickel alloy – C-22 And CW2M
High-Temperature Carbon Steel – A105 And WCB
Low-temperature carbon steel – LF2 And LCC
Bipolar UNS S32760 And 6A
For other wetted materials, please consult the manufacturer.
Flange options
ANSI 150 To 1500 Level
DIN PN 10 To PN 160
JIS 10K To 40K
Flange surfaces have multiple orientations.
For other flange specifications, please consult the manufacturer.
Operating temperature
-330 ° F To 800 ° F ( -200 ° C To 427 ° C )
Pipe diameter
Flanged: 1/2" To 12" ( 5 To 300mm )
Clamp-style: 1/2" To 8" ( 15 To 200 mm )
Dual-head type: 1/2" To 12" ( 15 To 300mm )
Reducer : 1" To 14" ( 25 To 350mm )
Features
-
The isolated sensor design enables online replacement without compromising the process seal.
-
It features a unique gasket-free instrument body design, enhancing factory usability while reducing potential leak points.
-
Non-clogging instrument body design eliminates process shutdowns and maintenance costs associated with clogged, pipeline-related issues.
-
Achieve vibration resistance through a mass balance sensor, and perform adaptive processing of digital signals via a visual filtering function.
-
Each flowmeter is equipped with a standard internal signal generator, simplifying the calibration of electronic components.
-
All flow meters undergo pre-configuration and hydrostatic testing upon arrival, ensuring convenient, immediate installation.
-
Using dual-head vortex flowmeters and quad-head vortex flowmeters simplifies SIS compliance.
-
Utilize Smart Fluid Diagnostics to detect the transition from liquid to gas phase.