ABB Electromagnetic Flowmeter


Classification:

Key words:


24-hour service hotline:+86-22-59958977

 

Bidding authorization:+86 13821081088


  • Product Description
    • Commodity name: ABB Electromagnetic Flowmeter
    • Commodity ID: FXE4000

    Instrument Specifications
    FXE4000 The series of electromagnetic flowmeters are field instruments that measure flow based on Faraday's law of electromagnetic induction, and they can accurately gauge conductive liquid media. Each electromagnetic flowmeter consists of two main components: the sensor and the converter, which can either be integrated into a single unit or designed as separate, remotely located parts. In the case of split-type electromagnetic flowmeters, the sensor and converter must be connected via a cable, with the cable typically available in various lengths to suit different installation requirements. 50 Meters are available in various models, including standard, explosion-proof, and hygienic types—each of which is explained below. ,
    Sensor
    The electromagnetic flowmeter's sensor features a simple design with no moving parts. It is available in flanged and clamp-style connection options, providing flexibility for installation. DVGW Test reports and certifications for cold water, wastewater, and non-water fluids are available. 4 Types of lining materials and 5 Selection of electrode materials. Regarding grounding methods, two solutions are available: a grounding ring and a grounding electrode. Additionally, lining protection plates and protective flanges can also serve as effective grounding components. Below are the specific specification parameters:

                Caliber range: DN 3 ~ DN 1000
                Connection method:    Flanged, ANSI , DIN, And JIS Clamping type
                Pressure rating: DIN PN10 ~ PN40 ANSI 150#, 300# (ANSI 600# Optional )
                Lining material:    Hard rubber, soft rubber, PTFE And PFA
                Electrode material:    Stainless steel 316Ti Hastelloy alloy B2/C4 Tantalum, titanium, and platinum-iridium alloy
                Flange material options: carbon steel, stainless steel 1.4571 ( 316Ti )
                Temperature resistance range: -25 ~ 90°C (Soft, Hard Rubber) -25 ~ 130°C ( PTFE , PFA )
                Ambient temperature: -20 ~ 60°C
                Protection rating: IP67 Or IP68
                System accuracy:    Indicated value ±0.5% (Available upon request ±0.25% The product)
                Excitation frequency: 6-1/4 Hz 、 7.5 Hz to 15 Hz And 25 Hz (Available for DN3 ~ DN100 The sensor
    Converter
    The electromagnetic flow converter comes in a one-piece design, a field-mountable type, and 3 A cabinet-style installation option is available, and the internal electronic boards feature a modular design for easy maintenance and replacement. The external EEPROM All the configuration information for the instruments can be stored, so when it's time to replace the transmitter, you simply transfer the external settings from the old unit. EEPROM The chip writes data into the new display, and after power-on, the converter automatically reads the information stored in the chip—eliminating the need for manual configuration of the new display. This significantly reduces on-site maintenance and debugging time, while also providing a dual backup of the instrument’s configuration data. Local configuration can be easily performed using a magnetic wand, eliminating the need to open the front cover.
    Here are the specific specification parameters:
                Case material:    Die-cast aluminum, or stainless steel (suitable for sanitary applications)
                Display locally:    Backlit LCD Display
                Communication method: HART Digital communication, PROFIBUS DP 、 PROFIBUS PA And FF
                On-site configuration method:    On-site configuration buttons, magnetic rod operation
                Power supply:       High Voltage: 85 ~ 253 VAC Low voltage: 16.8 ~ 26.4 VAC / 16.8 ~ 31.2 VDC
                Output:       4 ~ 20mA , pulse, node input / Output

    Calibration
    Each electromagnetic flowmeter undergoes actual-flow calibration before leaving the factory, and the calibration data sheet is shipped along with the meter.